INQUIRY

HOTLINE: +86 20 8489 8493

ONLINE QYY

E-MAIL: info@hncelectric.com

Product > Frequency Inverter > HV100W Series Frequency Inverter
HV100W Series Frequency Inverter
HV100W series is a general current vector control inverter integrated with the performance and features in a high degree, and high protection level (IP65). HV100W with industry-leading drive performance and functionality control, using unique current vect

HV100W series is a general current vector control inverter integrated with the performance and features in a high degree, and high protection level (IP65). HV100W with industry-leading drive performance and functionality control, using unique current vector control algorithm can efficiently drive induction motor to achieve high accuracy, high torque and high-performance control.

 

Exquisite appearance design, reliable hardware structure,dual display, independent air duct, powerful functions, rich macro parameters .ect. These optimized designs make HV100W series an industry-leading product and bring tangible benefits to customers.

 

Customer success, Market Service

 

HV100W in terms of performance and control are worthy of trust!

1. Advanced motor control technology support Open loop vector control(SVC) and V/F control. 

2. High protection level (IP65) is designed for unprotected use in all outdoor and bad environments.

3. Double-line digital display, can display more content

4. Powerful macro function, one-key setting, saving customer debugging time

5. Different input voltage(220V single phase/220V 3 phase/380V 3 phase/460V 3 phase).

6. High starting torque characteristics and precise speed control.

7. Upgrade I/O(NPN/PNP compatible) can meet more application requirement.

8. Programmable DI/DO/AI/AO, and Modbus RTU make easy communication with other devices.

9. Independent air duct design prevents dust from contacting the circuit board, better heat dissipation performance.

Model Definition:

Model

Input current (A)

Output current (A)

Adaptive motor

(KW) (HP)

G1 input voltage range: Single-phase AC220V±15%, 50 / 60 Hz

HV100W-R75G1

8.2

4.5

0.75

1

HV100W-1R5G1

14

7

1.5

2

HV100W-2R2G1

23

10

2.2

3

G2 input voltage range: Three-phase AC220V±15%, 50 / 60 Hz

HV100W-R75G2

5

4.5

0.75

1

HV100W-1R5G2

7.8

7

1.5

2

HV100W-2R2G2

10.5

10

2.2

3

HV100W-004G2

16.6

16

3.7

5

HV100W-5R5G2

26

20

5.5

7.5

HV100W-7R5G2

35

30

7.5

10

HV100W-011G2

46.5

42

11

15

HV100W-015G2

62

55

15

20

HV100W-018G2
75 70 18.5 25
HV100W-022G2
85 80 22 30
HV100W-030G2
115 110 30 40
HV100W-037G2
135 130 37 50
HV100W-045G2
165 160 45 60
HV100W-055G2
210 200 55 75

G3 input voltage range: Three-phase AC 380~440 (-15%~+10%), 50 / 60 Hz

HV100W-R75G3

3.4

2.5

0.75

1

HV100W-1R5G3

5

3.7

1.5

2

HV100W-2R2G3

5.8

5

2.2

3

HV100W-004G3

10.5

9

4.0

5

HV100W-5R5G3

14.6

13

5.5

7.5

HV100W-7R5G3

20.5

17

7.5

10

HV100W-011G3

26

25

11

15

HV100W-015G3

35

32

15

20

HV100W-018G3

38.5

37

18.5

25

HV100W-022G3

46.5

45

22

30

HV100W-030G3

62

60

30

40

HV100W-037G3
80 75 37 50
HV100W-045G3
94 90 45 60
HV100W-055G3
128 110 55 75
HV100W-075G3
160 150 75 100
HV100W-093G3
190 176 93 125
HV100W-110G3
225 210 110 150

G4 input voltage range: Three-phase AC 460~480 (-15%~+10%), 50 / 60 Hz

HV100W-R75G4

3.4

2.5

0.75

1

HV100W-1R5G4

5

3.7

1.5

2

HV100W-2R2G4

5.8

5

2.2

3

HV100W-004G4

10.5

9

4.0

5

HV100W-5R5G4

14.6

13

5.5

7.5

HV100W-7R5G4

20.5

17

7.5

10

HV100W-011G4

26

25

11

15

HV100W-015G4

35

32

15

20

HV100W-018G4

38.5

37

18.5

25

HV100W-022G4

46.5

45

22

30

HV100W-030G4

62

60

30

40

HV100W-037G4
80 75 37 50
HV100W-045G4
94 90 45 60
HV100W-055G4
128 110 55 75
HV100W-075G4
160 150 75 100
HV100W-093G4
190 176 93 125
HV100W-110G4
225 210 110 150

Standard specifications:

Input

Rating Voltage 

Frequency

Three-phase (G3/G4 series) 380V-480V50/60HZ

Single&Three-phase (G1/G2 series)  220 V: 50/60 Hz

Allowable range

of voltage

Three-phase (G3 series) : AC 380~440 (-15%~+10%)

Three-phase (G4 series) : AC 460~480 (-15%~+10%)

Single&Three-phase (G1/G2 series) : AC220V±15%

Output

Voltage

G1/G2 series; 0220V, G3 series; 0440 V, G4 series; 0480 V

Frequency

Low frequency mode: 0 ~ 300 Hz; high frequency mode: 0 ~ 3000 Hz

Overload capacity

G type machine: 110% long-term; 150% 1 minute ;200% 4 seconds

P type machine: 105% long-term ;120% 1 minute; 150% 1 second

Control mode

V/F control, advanced V/F control, V/F separation control and PG-free current vector control

Control characteristic

Frequency setting

Resolution

Analog end input

0.1% of the maximum output frequency

Digital settings

0.01Hz

Frequency accuracy

Analog input

Within 0.2% of the maximum output frequency

Digital input

Set the output frequency within 0.01%

V/F control

V/F curve (voltage frequency characteristic)

The reference frequency can be set arbitrarily from 0.5 Hz to 3000 Hz, and the multi-point V/F curve can be set arbitrarily. You can also choose a variety of fixed curves such as constant torque, torque reduction 1, torque reduction 2 and square torque

Torque boost

Manual setting: 0.0 ~ 30.0% of rated output

Automatic boost: automatically determine the boost torque according to the output current and motor parameters

Automatic current and voltage limiting

Whether in acceleration, deceleration or stable operation, the motor stator current and voltage can be automatically detected, which can be suppressed within the allowable range according to the unique algorithm to minimize the possibility of system fault tripping

Control characteristic

Sensorless vector control

voltage frequency characteristic

Automatically adjust output voltage-frequency ratio according to motor parameters and unique algorithm

Torque characteristic

Starting torque:

150% rated torque at 3.0Hz (VF control)

150% rated torque at 1.0Hz (advanced VF control)

150% rated torque at 0.5Hz (without PG current vector control)

Running speed steady-state accuracy: ≤± 0.2% rated synchronous speed

Speed fluctuation: ≤± 0.5% rated synchronous speed

Torque response: ≤20ms (without PG current vector control)

Self-determination of motor parameters

Without any restriction, the parameters can be automatically detected under static and dynamic conditions to obtain the best control effect

Current and voltage suppression

Full-range current closed-loop control, completely avoiding current impact, with perfect overcurrent and overvoltage suppression function

Running

undervoltage suppression

Especially for users with low grid voltage and frequent fluctuation of grid voltage, the system can maintain the longest possible operation time according to the unique algorithm and residual energy allocation strategy even in the range below the allowable voltage

Typical function

Multi speed and

Swing frequency operation

16-stage programmable multi-stage speed control and multiple operation modes are optional. Swing frequency operation: preset frequency and center frequency can be adjusted, and state memory and recovery after power failure

PID control

RS485 communication

Built-in PID controller (preset frequency). Standard configuration RS485 communication function, multiple communication protocols can be selected, with linkage synchronous control function

Frequency setting

Analog input

DC voltage 0 ~ 10 V, DC current 0 ~ 20 mA (upper and lower limits are optional)

Digital input

keypad setting, RS485 interface setting, UP/DOWN terminal control, and various combination settings with analog input can also be made.

Output signal

Digital output

2 Y-terminal open collector outputs and two programmable relay outputs (TA/TB/TC), with up to 61 functions

Analog output

2 analog signals are output, and the output range can be flexibly set between 0 ~ 20mA or 0 ~ 10V, which can realize the output of physical quantities such as set frequency and output frequency

Automatic voltage stabilizing operation

According to the needs, three modes can be selected: dynamic voltage stabilization, static voltage stabilization and non-voltage stabilization, so as to obtain the most stable operation effect

Acceleration and deceleration

Time setting

0.1s3600.0min can be set continuously, and S-type and linear mode can be selected

Brake

Energy

consumption

Brake

Energy consumption braking starting voltage, return difference voltage and energy consumption braking rate can be continuously adjusted

Direct current

Brake

Starting frequency of DC braking during shutdown: 0.00 ~ [000.13] upper limit frequency

Braking time: 0.0 ~ 100.0 s; Braking current: 0.0% ~ 150.0% rated current

Magnetic flow

Brake

0 ~ 100 0: invalid

Low noise operation

The carrier frequency is continuously adjustable from 1.0 kHz to 16.0 kHz to minimize the noise of the motor

Revolving speed tracking speed

Restart facility

It can realize the smooth restart and instantaneous stop restart of the motor in operation

Counter

One internal counter is convenient for system integration

Operating function

Upper and lower limit frequency setting, frequency jump operation, reverse operation limit, slip frequency compensation, RS485 communication, frequency increment and decrement control, fault self-recovery operation, etc


Display

keypad display

Running

State

Output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback amount, analog input and output, etc

Alarm

Content

The last six fault records, the record of six operation parameters such as output frequency, set frequency, output current, output voltage, DC voltage and module temperature during the last fault trip.

Protection function

Over-current, over-voltage, under-voltage, module failure, electronic thermal relay, overheating, short circuit, input and output phase failure, abnormal tuning of motor parameters, internal memory failure, etc.

Environment

Ambient temperature

-10 ~+40 (the ambient temperature is 40 ~ 50, please use it at a reduced level)

Ambient humidity

5% ~ 95% RH, no water condensation

Surrounding environment

Indoor (no direct sunlight, corrosion, flammable gas, oil mist, dust, etc.)

Altitude

1000 meters above the use of derating, every 1000 meters up derating 10%

Structure

Protection grade

IP65

Cooling mode

Air-cooled with fan control

    Installation method

Wall mounted, cabinet mounted


Model

A

(mm)

B

(mm)

H

(mm)

W

(mm)

W1

(mm)

D

(mm)

Install Hole

(mm)

Installation

Exterior

HV100W-R75G1/2

80

240

250

140

110

190

5

HV100W-1R5G1/2

HV100W-2R2G1/2

HV100W-R75G3/G4

HV100W-1R5G3/G4

HV100W-2R2G3/G4

HV100W-004G3/G4

HV100W-004G2

120

290

305

185

155

210

6

HV100W-5R5G2

HV100W-5R5G3/G4

HV100W-7R5G3/G4

HV100W-011G3/G4

HV100W-7R5G2

160

360

375

240

210

200

7

HV100W-011G2

HV100W-015G2

HV100W-015G3/G4

HV100W-018G3/G4

HV100W-022G3/G4

HV100W-030G3/G4

HV100W-018G2

200

482

500

300

270

230

7

HV100W-022G2

HV100W-037G3/G4

HV100W-045G3/G4

HV100W-030G2

245

520

540

345

315

290

9

HV100W-037G2

HV100W-055G3/G4

HV100W-075G3/G4

HV100W-045G2

270

555

575

380

350

320

9

HV100W-055G2

HV100W-093G3/G4

HV100W-110G3/G4




Series Model Download
Frequency Inverter HV100W Series Frequency Inverter User Manual-V7.3
Frequency Inverter HV100&HV100W Series Frequency Inverter Catalog-V2.0
About HNC
Company Overview Vision and Mission HNC Growth History
Product
PLC HMI CNC Controller Servo Drive Frequency Inverter Spindle Motor AC Servo Motor Accessories Sensor
Solution
Packaging & Printing CNC Machine Tool Textile Fan & Pump Converting Elevator Crane Plastic Industry
Service
DownLoad FAQ Warranty
News Center
HNC news