PRODUCT
- HCS Series Card type PLC HCG Series Card type PLC HCM Series Card type PLC HCD2 Series Card type PLC HCM2 Series Card type PLC HCH2 Series Card type PLC HCG2 Series Card type PLC HCS2 Series Card type PLC
- H-BOX Series IoT Box H-BOX-M Series IoT Box HT3000-A Series IoT HMI HT3000-B Series IoT HMI HT3000-D Series IoT HMI
- HNC-808 series HNC-818 series HNC-848 series 606T CNC controller for Turnning Machine 606M CNC controller for Milling Machine 602T CNC controller for Turning Machine
- SV-E3 Series Synchronous Servo System HSD7 Series High-end Synchronous Servo Drive HSD2 Series Synchronous Servo Drive HSD6 Series Synchronous Servo Drive HSV-180AD AC380V Servo Drive HSV-180AS Spindle Servo Drive HSD2000 AC380V Servo Drive
- HV320 Series Frequency Inverter HV100W Series Frequency Inverter HV10 Series Mini Design Frequency Inverter HV100 Series High Performance Frequency Inverter HV480 Series High Performance Frequency Inverter HV610 Series High Performance Frequency Inverter HV580L Series Elevator Inverter HRS Series High Performance Soft Starter
- GM6 series spindle motor GM7 series spindle motor
- HSM (AC380V) Series Servo Motor HSM (AC220V) Series Servo Motor
- HNC Braking Unit Gear Boxes
- Rotary Encoder Proximity Sensor Photoelectric Sensor Area Sensor


New HV100 series is a general current vector control inverter integrated with the performance and features in a high degree. HV100 with industry-leading drive performance and functionality control, using unique current vector control algorithm can efficiently drive induction motor to achieve high accuracy, high torque and high-performance control.
Exquisite appearance design, reliable hardware structure, detachable keyboard, dual display, independent air duct, powerful functions, rich macro parameters .ect. These optimized designs make HV100 series an industry-leading product and bring tangible benefits to customers.
Customer success, Market Service!
HV100 in terms of performance and control are worthy of trust!
1. Advanced motor control technology support Open loop vector control(SVC) and V/F control.
2. Double-line digital display, can display more content
3. Powerful macro function, one-key setting, saving customer debugging time4. Different input voltage(220V single phase/220V 3 phase/380V 3 phase/460V 3 phase).
5. High starting torque characteristics and precise speed control.
6. Suitable for all regions which have different grid and voltage.
7. Upgrade I/O(NPN/PNP compatible) can meet more application requirement.
8. Programmable DI/DO/AI/AO, and Modbus RTU make easy communication with other devices.
9. Detachable keyboard,support keyboard extension, convenient for customer debugging.
10. Independent air duct design prevents dust from contacting the circuit board, better heat dissipation performance.
11. Installation back mounting system can insert the inverter directly into the rack.
12. Integrated multi-speed function support most of texitile application.
Model Definition:
Model
Input current (A)
Output current (A)
Adaptive motor
(KW) (HP)
G1 input voltage range: Single-phase AC220V±15%, 50 / 60 Hz
HV100-R40G1
5.4
2.3
0.4
0.5
HV100-R75G1
8.2
4.0
0.75
1
HV100-1R5G1
14
7.0
1.5
2
HV100-2R2G1
23
9.6
2.2
3
G2 input voltage range: Three-phase AC220V±15%, 50 / 60 Hz
HV100-R40G2
3.4
2.1
0.4
0.5
HV100-R75G2
5
3.8
0.75
1
HV100-1R5G2
5.8
5.1
1.5
2
HV100-2R2G2
10.5
9
2.2
3
HV100-004G2
14.6
13
3.7
5
HV100-5R5G2
26
25
5.5
7.5
HV100-7R5G2
35
32
7.5
10
HV100-011G2
46.5
45
11
15
HV100-015G2
62
60
15
20
G3 input voltage range: Three-phase AC 380~440 (-15%~+10%), 50 / 60 Hz
HV100-R75G3
3.4
2.1
0.75
1
HV100-1R5G3
5
3.8
1.5
2
HV100-2R2G3
5.8
5.1
2.2
3
HV100-004G3
10.5
9
4.0
5
HV100-5R5G3
14.6
13
5.5
7.5
HV100-7R5G3
20.5
17
7.5
10
HV100-011G3
26
25
11
15
HV100-015G3
35
32
15
20
HV100-018G3
38.5
37
18.5
25
HV100-022G3
46.5
45
22
30
HV100-030G3
62
60
30
40
Standard specifications:
Input
Rating Voltage ,
Frequency
Three-phase (G3/G4 series) 380V-480V, 50/60HZ
Single&Three-phase (G1/G2 series) 220 V: 50/60 Hz
Allowable range
of voltage
Three-phase (G3 series) : AC 380~440 (-15%~+10%)
Three-phase (G4 series) : AC 460~480 (-15%~+10%)
Single&Three-phase (G1/G2 series) : AC220V±15%
Output
Voltage
G1/G2 series; 0~220V, G3 series; 0~440 V, G4 series; 0~480 V
Frequency
Low frequency mode: 0 ~ 300 Hz; high frequency mode: 0 ~ 3000 Hz
Overload capacity
G type machine: 110% long-term; 150% 1 minute ;200% 4 seconds
P type machine: 105% long-term ;120% 1 minute; 150% 1 second
Control mode
V/F control, advanced V/F control, V/F separation control and PG-free current vector control
Control characteristic
Frequency setting
Resolution
Analog end input
0.1% of the maximum output frequency
Digital settings
0.01Hz
Frequency accuracy
Analog input
Within 0.2% of the maximum output frequency
Digital input
Set the output frequency within 0.01%
V/F control
V/F curve (voltage frequency characteristic)
The reference frequency can be set arbitrarily from 0.5 Hz to 3000 Hz, and the multi-point V/F curve can be set arbitrarily. You can also choose a variety of fixed curves such as constant torque, torque reduction 1, torque reduction 2 and square torque
Torque boost
Manual setting: 0.0 ~ 30.0% of rated output
Automatic boost: automatically determine the boost torque according to the output current and motor parameters
Automatic current and voltage limiting
Whether in acceleration, deceleration or stable operation, the motor stator current and voltage can be automatically detected, which can be suppressed within the allowable range according to the unique algorithm to minimize the possibility of system fault tripping
Control characteristic
Sensorless vector control
voltage frequency characteristic
Automatically adjust output voltage-frequency ratio according to motor parameters and unique algorithm
Torque characteristic
Starting torque:
150% rated torque at 3.0Hz (VF control)
150% rated torque at 1.0Hz (advanced VF control)
150% rated torque at 0.5Hz (without PG current vector control)
Running speed steady-state accuracy: ≤± 0.2% rated synchronous speed
Speed fluctuation: ≤± 0.5% rated synchronous speed
Torque response: ≤20ms (without PG current vector control)
Self-determination of motor parameters
Without any restriction, the parameters can be automatically detected under static and dynamic conditions to obtain the best control effect
Current and voltage suppression
Full-range current closed-loop control, completely avoiding current impact, with perfect overcurrent and overvoltage suppression function
Running
undervoltage suppression
Especially for users with low grid voltage and frequent fluctuation of grid voltage, the system can maintain the longest possible operation time according to the unique algorithm and residual energy allocation strategy even in the range below the allowable voltage
Typical function
Multi speed and
Swing frequency operation
16-stage programmable multi-stage speed control and multiple operation modes are optional. Swing frequency operation: preset frequency and center frequency can be adjusted, and state memory and recovery after power failure
PID control
RS485 communication
Built-in PID controller (preset frequency). Standard configuration RS485 communication function, multiple communication protocols can be selected, with linkage synchronous control function
Frequency setting
Analog input
DC voltage 0 ~ 10 V, DC current 0 ~ 20 mA (upper and lower limits are optional)
Digital input
keypad setting, RS485 interface setting, UP/DOWN terminal control, and various combination settings with analog input can also be made.
Output signal
Digital output
2 Y-terminal open collector outputs and two programmable relay outputs (TA/TB/TC), with up to 61 functions
Analog output
2 analog signals are output, and the output range can be flexibly set between 0 ~ 20mA or 0 ~ 10V, which can realize the output of physical quantities such as set frequency and output frequency
Automatic voltage stabilizing operation
According to the needs, three modes can be selected: dynamic voltage stabilization, static voltage stabilization and non-voltage stabilization, so as to obtain the most stable operation effect
Acceleration and deceleration
Time setting
0.1s~3600.0min can be set continuously, and S-type and linear mode can be selected
Brake
Energy
consumption
Brake
Energy consumption braking starting voltage, return difference voltage and energy consumption braking rate can be continuously adjusted
Direct current
Brake
Starting frequency of DC braking during shutdown: 0.00 ~ [000.13] upper limit frequency
Braking time: 0.0 ~ 100.0 s; Braking current: 0.0% ~ 150.0% rated current
Magnetic flow
Brake
0 ~ 100 0: invalid
Low noise operation
The carrier frequency is continuously adjustable from 1.0 kHz to 16.0 kHz to minimize the noise of the motor
Revolving speed tracking speed
Restart facility
It can realize the smooth restart and instantaneous stop restart of the motor in operation
Counter
One internal counter is convenient for system integration
Operating function
Upper and lower limit frequency setting, frequency jump operation, reverse operation limit, slip frequency compensation, RS485 communication, frequency increment and decrement control, fault self-recovery operation, etc
Product Outline, Mounting Dimension