INQUIRY

HOTLINE: +86 20 8489 8493

ONLINE QYY

E-MAIL: info@hncelectric.com

Product > Frequency Inverter > HV10E Series Frequency Inverter
HV10E Series Frequency Inverter
HV10E is HNC Electrics economic mini-series AC inverter, retaining core vector control performance in a compact, cost-effective design for small and medium-power automation equipment.

HV10E is the economic mini-series AC inverter from HNC Electric, built for small-power industrial automation applications. It supports both V/F control and speed-sensorless vector control (SVC), covering single-phase AC220V (0.4–2.2kW) and three-phase AC380V (0.75–2.2kW), suitable for small pumps, fans, conveyors, and general light-load equipment. With built-in PID, multi-speed function, application macros for water-supply scenarios, and standard RS485 Modbus communication, HV10E offers customers an easy-to-use and cost-effective solution.

1.Mini compact housing (147×72×132mm), suitable for space-constrained equipment and cabinet installation

2.V/F + SVC vector control dual modes, balancing cost and control performance

3.Built-in PID function, supports applications such as single-pump constant-pressure water supply

4.Macro function presets (single-pump water supply / PV water supply voltage tracking / PV water supply power tracking), one-key switching for typical applications, saving commissioning time

5.16-segment multi-speed function, suitable for textile, packaging and other multi-speed applications

6.Standard RS485 Modbus RTU communication, convenient for networking with PLC/host computer

7.Rich I/O interfaces: 4 digital inputs, 1 relay output, 2 analog inputs, 1 analog outputs

8.Strong overload capacity and comprehensive protection: 150% rated current for 60s overload, with overcurrent, overvoltage, phase-loss and other multiple protections

Voltage level

Rated power (KW)

Rated output current (A)

Adapted motor (KW)

220V single phase

0.4

2.4

0.4

0.75

4.5

0.75

1.5

7.0

1.5

2.2

10

2.2

380V three-phase

0.75

2.5

0.75

1.5

3.7

1.5

2.2

5

2.2


Input

Rated voltage, frequency

Three-phase  AC380V, 50/60HZ

Single phase AC220V: 50/60 Hz

Voltage allowed

Range of  change

Three-phase (G3 series) : AC 380~440 (-15%~+10%)

Single phase (G1-2 series) : AC220V±15%

Output

Voltage

G1-2 series; 0220V, G3 series; 0440 V

Frequency

Vector control: 0500Hz V/F control: 05000Hz

Overload capacity

150% rated current for 60s180% rated current for 3s

Control method

V/F control, speed sensorless vector control (SVC)

Control characteristics

Frequency setting resolution

Analog input

Maximum frequency×0.025%

Digital settings

0.01Hz

V/F control

V/F curve

Three methods: linear typemulti-point type;

N-th power V/F curve

(1.2 power, 1.4 power, 1.6 power, 1.8 power, 2 power)

V/F separation

2 ways: full separation, semi-separation

Torque boost

Manual setting: 0.030.0% of rated output Automatic lifting: automatically determine the lifting torque according to the output current and combined with the motor parameters

Automatic current limiting and pressure limiting

Whether during acceleration, deceleration or stable operation, it can automatically detect the motor stator current and voltage, and suppress it within the allowable range based on a unique algorithm to minimize the possibility of system fault tripping.

Inductive vector control

Voltage frequency

characteristics

Automatically adjust the output voltage-to-frequency ratio based on motor parameters and unique algorithm

Torque characteristics

Starting torque:

150% rated torque at 3.0Hz (V/F control) 150% rated torque at 0.5Hz (vector control

without SVC vector)

Operating speed steady-state accuracy: ≤±0.2% rated synchronous speed

Speed fluctuation: ≤±0.5% rated synchronous speed

Torque response: ≤20ms (vector control without speed sensor)

Self-determination of  motor parameters

Without any restrictions, automatic parameter detection can be completed under both static and dynamic conditions of the motor to obtain the best control effect.

Current and voltage suppression

Full-range current closed-loop control, completely avoiding current impact, with perfect overcurrent and overvoltage suppression function

Under voltage suppression

during

operation

Especially for users with low grid voltage and frequent fluctuations in grid voltage, even if the voltage is lower than the allowed voltage range, the system can maintain the longest possible operating time based on a unique algorithm and residual energy allocation strategy.

Typical functions

Multi-speed and swing frequency operation

16-segment programmable multi-segment speed control, multiple operating modes available. Swing frequency operation: preset frequency and center frequency are adjustable, state memory and recovery after power outage

PID control RS485 communication

Built-in PID controller (frequency can be preset), standard configuration RS485 communication function

Frequency setting

Analog input

DCvoltage010V,DCcurrent020mA(upper and lower limits optional)

digital input

Operation panel setting, RS485 interface setting, UP/DOWN terminal control, and various combination settings with analog input

output signal

digital output

 1 programmable relay outputs(TA,TC) with up to 58 meaning options

Analog output

1 analog signal outputs, the output range can be flexibly set between020mA or 010V, which can realize the output of physical quantities such as set frequency and output frequency.

Automatic voltage stabilization operation

You can choose dynamic voltage stabilization, static voltage stabilization, or not stabilized voltage according to your needs to obtain the most stable operating effect.

Acceleration and deceleration time setting

0.0s6500.0s can be set continuously, S-shaped and linear modes are

optional

brake

Energy consumption

brake

Energy consumption braking starting voltage, hysteresis voltage and energy consumption braking rate are continuously adjustable

DC brake

Stop DC braking starting frequency: 0.00[F00.10] maximum frequency

Braking time: 0.0100.0sBraking current: 0%100% rated current

 

Low noise operation

The carrier frequency is continuously adjustable from 0.5KHz to 16.0KHz to minimize motor noise.

RPM tracking speed restart function

It can realize smooth restart and instantaneous stop restart function of the running motor.

counter

An internal counter to facilitate system integration

run function

Upper and lower limit frequency settings, frequency jump operation,reverse operation limit, slip frequency compensation, RS485 communication, frequency increase and decrease control, fault self-recovery operation, etc.

Display

Operation panel display

run state

Output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback amount, analog input and output, etc.

alarm content

There are 8 operating parameter records including output frequency, set frequency,output current,output voltage,DC voltage,module temperature, power-on time, and running time when three faults trip.

Protective function

Overcurrent, overvoltage, undervoltage, module failure, electronic thermal relay, overheating, short circuit, input and output phase loss, abnormal motor parameter tuning, internal memory failure, etc.

environment

ambient temperature

-10℃+40℃ (environment temperature is between 40℃50℃, please derate for use)

ambient humidity

5%95%RH, no water droplets condensation

surroundings

Indoor (no direct sunlight, no corrosion, flammable gas, oil mist, dust, etc.)

altitude

Derating for use above 1000 meters, derate by 10% for every 1000 meters.

structure

Protection level

IP20

cooling method

Air-cooled, with fan control

Installation method

Wall-mounted, cabinet type


H

(mm)

W

(mm)

D

(mm)

H1

(mm)

W1

(mm)

Mounting Holes

(mm)

External dimensions

Installation dimensions

147

72

132

136

63

4

Series Model Download
Frequency Inverter HV10E Series Frequency InverterUser Manual-V2.1
* If clicking the download button does not respond, it may be because the browser has blocked the file.
Please follow the steps below to check and enable download permissions:
Click the padlock icon in the address bar or go to Settings → Privacy and Security → Site Settings →
Insecure Content, and allow this site to load insecure content. After that, the compressed file should download properly.
About HNC
Company Overview Vision and Mission HNC Growth History
Product
PLC HMI CNC Controller Servo Drive Frequency Inverter Spindle Motor AC Servo Motor Accessories Sensor
Solution
Packaging & Printing CNC Machine Tool Textile Fan & Pump Converting Elevator Crane Plastic Industry
Service
DownLoad FAQ Warranty
News Center
HNC news